A cable is a tension-only member that sags under its self-weight. As pretension increases, the sag decreases, and the cable becomes taut, behaving more like a straight truss. If the sag effect is ignored, the cable's axial stiffness and frequency will be overestimated. The pretension also contributes to the cable's geometric stiffness and its transverse vibration modes.
This article explains how MIDAS CIVIL NX accounts for both these effects and how we can set up an eigenvalue analysis for cable structures. We've also included verification of the eigenvalue analysis for a 5 m long cable under different pretension loads, accounting for both sag effects and geometric stiffness.
In MIDAS CIVIL NX, the tension-only cable element reflects the change in stiffness as a function of its internal tension force. For eigenvalue analysis, cable elements are converted into equivalent truss elements.
The axial stiffness of a truss element is:
Kelastic = EA / L
The resultant axial stiffness of a cable is a series combination of the elastic and sag stiffnesses:
Keq = 1 / (1/Kelastic + 1/Ksag) = EeqA / L
The Ernst equation gives the equivalent modulus of elasticity,
Eeq = E / [1 + (w2L2EA) / (12T3)]
The element stiffness matrix of a cable element can be separated into two parts: the elastic stiffness matrix, kE, and the geometric stiffness matrix, kG. The approximation T/L ≈ T/L0 is accurate enough for most applications.
Figure 1. Elastic and geometric stiffness matrices of an equivalent truss element
You can check more of these details in the download file.